Stress Photonics GFP 1200 Grey-Field Polariscope

This full-field photoelastic strain measurement system features automated data acquisition and processing. The extremely sensitive system can measure shear strain magnitude and direction without high-strain photoelastic fringes. The GFP 1200 utilises Stress Photonics' DeltaVision software for detailed analysis and high quality presentation.

 
 
Key Features of the GFP 1200
 
  • Automated full-field strain measurement
  • Compatible with all coatings
  • Thickness measurement via tinted coatings
  • 20 microstrain resolution typical
  • Sub-fringe or multi-fringe
  • Simple static loading
  • Traceable system calibration
  • No fringes to analyse
  • Automatic measurement of coating thickness
  • Fully computerized digital system
  • Thin easy-to-apply coatings
  GFP 1200 Equipment

 
 
Software
 
Screenshot from DeltaVision Software
 
 
 
  The full-field strain images can be analysed via the easy to use DeltaVision software. The software allows GFP 1200 users to take advantage of powerful Windows software and network resources to process and present data quickly and easily. DeltaVision works easily with popular word processing and graphic presentation software such as Microsoft Word and PowerPoint. Images and data information can quickly and easily be copied and pasted from DeltaVision to other Windows applications.
 
 
 
The GFP 1200 is well suited to the following engineering applications:
 
  • Locating 'Hot Spots' - High Strain Areas
  • Verifying FEA Models
  • Load Stepping Techniques
  • Analysing Dynamic Loading Situations with High Frequency (kHz) Stroboscopic System
  • Oblique Incidence Photoelasticity
  • Performing Strain Analysis on Stereolithography Models
  • Monitoring Fatigue Tests in Progress
  • Visualising Residual Strains in Glass and Plastic
  GFP 1200 System

 
 
Technical Specifications
 
  
System Performance
 
Typical Strain Resolution   20 Microstrain (1/100 fringe order)
Spatial Resolution   320 x 240
Typical Image Acquisition Time   10s
Image Acquisition   PCI Frame Grabber Card
Thickness Measurement
(with tinted coating)
  ± 5% Accuracy
 
  
Camera
 
Optics   Standard Camera Lenses
(eg 28-70mm zoom, 17mm, 90mm)
Detector   CCD
Power   100-250 VAC
Size (without lens)   20cm x 9.5cm x 9.5cm
(7.8in x 3.75in x 3.75in)
Weight   1.6 kg (3.5lb) with lens
 
  
Projector
 
Power   100-250 VAC
Size   23.2cm x 9.5cm x 9.5cm
(9.2in x 3.75in x 3.75in)
Weight   1.6kg (3.5lb)
Achromatic Projected Light   150W Bulb
 
  
Computer Hardware and Software
 
DeltaVision Software   Controls system parameters, image acquisition, and post-processing. Runs under Windows NT operating system.
System Computer   Selection of notebook & desktop computers.
 
 
 
To discuss how you can benefit from the GFP 1200 please Contact Us